
Precio de origen
$ 63.074
+ flete y aranceles — se calculan al cotizar
Compra protegida
Puerta a puerta
Aduana incluida
Product description GVD-RMA PL 4641600 Vent Damper Motor Assembly Compatible with Field Controls NOTE: Before purchasing, please carefully diagnose the reason for the damper not working and make sure it is caused by the damaged motor to avoid the damper still not working after installing a new motor. HOW TO DETERMINE THE MOTOR DAMAGE? Make sure damper is in the open position. Use the service switch to keep thedamper in the open position. Place a jumper between 2&3.If the appliance fires, remove jumper & plug receptacle backinto damper controller plug. If appliance does not fire, replace damper motor assembly. Do not replace the pipe assembly. CAUTlON: When servicing controls, all wires must be labeled prior todisconnection. Wiring errors can cause improper and dangerous operation. Do not turn damper open manually or motor damage will result, use the service switch. GVD-RMA PL Vent Damper Motor is compatible with GVD model dampers Including GVD-4PL, GVD-5PL, GVD-6PL, GVD-7PL, GVD-8PL, GVD-9PL, GVD-10PL, GVD-12PL.Please check this 46491600 Boiler Damper Motor is compatible with your boiler model before purchasing. 46491600 Vent Damper Motor Assembly GVD motor is easy to install and can save you the cost of replacing the entire damper. Insert the boiler damper con-rod into the GMA-PL motor.Use the Screws to secure it.Connect the wiring harness correctly. Warm Tips If your current motor is damaged and cannot run automatically, you can turn the motor button to "hold open" mode and then use a pair of pliers to manually rotate the con-rod to allow the damper to open.After opening the damper manually, when the boiler goes out, the damper cannot close automatically, which can result in some heat loss. Please replace the damaged motor promptly. Technical Data: Input voltage: 24VAC Motor type: Synchronous motor Power consumption: 4.5 watts Housing material: Plastic HOW DOES THE MOTOR WORK? The vent damper is installed in the exhaust duct, downstream of the hood or hazard management device. When the damper is in the closed position, it blocks airflow through the exhaust duct. When heat is required, the boiler receives a call for heat, the GVD motor activates, and the damper rotates through 90 degrees to the open position. The damper takes approximately 15 seconds to open or close. Once fully open, the burner ignites and the flue gases are exhausted through the vent pipe. Once the thermostat reaches the required level, the burner stops and the damper closes automatically. Adjustable Settings The boiler can be adjusted to automatic mode during normal working. If the boiler is not working properly and needs to be checked and serviced, the motor can be adjusted to hold on. Socket Easy Wiring During installation, the damper blades should be aligned with the GVD motor and the plug going into the motor should be properly keyed. Plastic Base The GMA-PL Boiler Vent Damper Motor base made of plastic,which is lightweight, chemically stable, non-corrosive. PLEASE CHECK AFTER REPLACING THE MOTOR Check that the damper and gas valve(s) are in the correct operating sequence. a. The damper must be in the full open position before the gas valve(s) opens. b. The damper must remain in the full open position while the gas valve(s) is open. c. The gas valve(s) must be closed before the damper begins its return to the closed position. d. The damper shall remain in the closed position during the off cycle of the appliance. See More
Agregás al carrito
Sumás este y otros productos que querés traer.
Cotizás el envío
Calculamos flete aéreo y aranceles a Argentina.
Confirmás y pagás
Un asesor te contacta con el link de pago.
Lo recibís en casa
Tracking en tiempo real. Aduana incluida.
Los mejor puntuados del mismo tipo de producto