
Precio desde
$ 324.724
+ flete y aranceles — se calculan al cotizar
Tamaño
Compra protegida
Puerta a puerta
Aduana incluida
Product description What Real-life Problems can be Solved by using ATO Single Phase to 3 Phase VFD? 220v-240v Single to three phase VFD can solve the problem of power phase mismatch, that is, the power supply is single-phase, and the equipment uses three-phase power.220V output VFD can solve the problem of power frequency mismatch, that is, the power supply is 50Hz/60Hz, and the equipment power consumption is 0.00~400.00Hz (arbitrarily set). What are the Benefits of using ATO 1 Phase to 3 Phase vfd? Reduce energy consumption and energy costs: Optimize V/F curve automatically based on the load to realize power save running.Extend equipment life and reduce maintenance. 10hp Single to 3 Phase VFD 15hp Single to 3 Phase VFD 20hp Single to 3 Phase VFD 25hp Single to 3 Phase VFD 40hp Single to 3 Phase VFD 50hp Single to 3 Phase VFD Add to Cart Add to Cart Add to Cart Add to Cart Buying Options Add to Cart Customer Reviews 4.5 out of 5 stars 6 4.8 out of 5 stars 4 4.0 out of 5 stars 1 — — — Price EUR 860.07EUR860.07 EUR 1,258.86EUR1,258.86 EUR 1,491.05EUR1,491.05 EUR 1,645.27EUR1,645.27 — no data EUR 2,474.08EUR2,474.08 Capacity 10 hp(7.5 kW) 15 hp (11 kW) 20 hp (15 kW) 25hp, 18.5kW 40hp, 30kW 50hp, 37kW Rated current(Output Current) 32 A 45 A 60 A 75 A 112 A 150 A Input voltage 1 phase 220~240V AC 1 phase 220~240V AC 1 phase 220~240V AC 1 phase 220~240V AC 1 phase 220~240V AC 1 phase 220~230V AC Input frequency 50Hz/ 60Hz 50Hz/ 60Hz 50Hz/ 60Hz 50Hz/ 60Hz 50Hz/ 60Hz 50Hz/ 60Hz Output voltage 3 phase AC 0~input voltage 3 phase AC 0~input voltage 3 phase AC 0~input voltage 3 phase AC 0~input voltage 3 phase AC 0~input voltage 3 phase AC 0~input voltage Output frequency 0.00~1000Hz 0.00~1000Hz 0.00~1000Hz 0.00~1000Hz 0.00~1000Hz 0.00~1000Hz Dimension 13″*7.9″*7.9″ 13″*7.9″*7.9″ 21″*12.6″*9.3″ 21″*12.6″*9.3″ 22″*12*10″ 25.6″ × 15″ × 11.8″ Shipping weight 16.5 lbs 16.5 lbs 48 lbs 48 lbs 66 lbs 112.5 lbs ATO 220V 230V 240V single phase to 3 phase VFD VSD, 220V 230V single phase to three phase VFD variable frequency drive, convert single phase to 3 phase for AC motor speed controls, RS485 enabled. vfd 220v input 220v 3 phase output widely used in spindle motor, drill press, CNC, compressor, milling, HVAC, lathe, pumps, conveyors, cooling, fan, and three phase motor. etc. Note: The rated current of the ATO single to 3 phase VFD refers to the three-phase output current. The input current of the ATO single to three phase VFD is approximately 1.5 times the output current. How to choose a right VFD? Except for the input voltage, there are two additional conditions that need to be met: 1. The rated current of the VFD should be greater than the rated current of your motor, preferably by at least 30%. 2. The rated power of the VFD should be greater than the rated power of your motor, preferably by at least one levels. If you're unsure which VFD is suitable for your motor, please provide us with a photo of your motor nameplate, tell us the input power supply, and your requirements. We'll then recommend the appropriate VFD model for you. Tips: Input frequency: 47-63Hz (so 50/60Hz is supported); Output frequency: 0-1000Hz (Default: 50Hz, if you need the output frequency to be 60Hz, please set: P0.02=60, P0.05=60, P0.06=60, P8.04=60) How to set the output frequency to 1000Hz? set: P0.05=1000. P0.06=1000 P8.04=1000, P0.21=1 ATO VFD 220V Input 220V 3 Phase Output Common Specification Capacity(Optional) 1/2 hp /1 hp /2 hp /3 hp /5 hp /7.5 hp /10 hp/15 hp/20 hp/25hp/40hp/50hp (optional) Over load capacity 150% of rated current for 1 minute, 180% of rated current for 3 seconds Control mode V/F control Communication RS485 Speed regulation 1:100 Start torque 150% of rating torque at 1 Hz Speed control accuracy ≤±0.5% of rating synchronous speed Frequency resolution Analog setting: 0.1% of max frequency; Digital setting: 0.01Hz Torque boost Automatic torque boost, manual torque boost 0.1%~30.0% Interior PID controller Be convenient to make closed-loop system Automatic energy save running Optimize V/F curve automatically based on the load to realize power save running Automatic voltage regulation Can keep constant output voltage when power source voltage varies. Enclosure rating IP 20
Agregás al carrito
Sumás este y otros productos que querés traer.
Cotizás el envío
Calculamos flete aéreo y aranceles a Argentina.
Confirmás y pagás
Un asesor te contacta con el link de pago.
Lo recibís en casa
Tracking en tiempo real. Aduana incluida.
Los mejor puntuados del mismo tipo de producto