
Precio desde
$ 2.439.521
+ flete e impuestos
Tamaño
Color
Compra protegida
Puerta a puerta
Gestión aduanera
Tu compra, acompañada de principio a fin
Todo esto está en los Términos y Condiciones. Leerlos
¿Es una compra grande? Repasala con una persona.
Te contamos cómo queda el costo total —flete, impuestos y aranceles— y cuánto tarda, antes de que pongas la tarjeta.
Escribinos por WhatsAppProduct description GoHz Frequency Converter 1 Phase Converter Add to Cart 3 Phase Converter Add to Cart 3 Phase Converter Add to Cart 3 Phase Converter Add to Cart Price $1,627.46$1,627.46 $6,709.24$6,709.24 $8,440.52$8,440.52 $15,507.88$15,507.88 Input Voltage 1 Phase 3 Phase 3 Phase 3 Phase Capacity 500VA-30kVA(option *) 3 kVA-45kVA(option *) 3 kVA-45kVA(option *) 3 kVA-45kVA(option *) Output Frequency 50Hz, 60Hz 50Hz, 60Hz 50Hz, 60Hz 50Hz, 60Hz Frequency Stability ≤±0.01% ≤±0.01% ≤±0.01% ≤±0.01% Harmonic Distortion Pure Sine Wave ≤2% Pure Sine Wave ≤2% Pure Sine Wave ≤2% Pure Sine Wave ≤2% GoHz Single Phase Frequency Converter Specification: Capacity 500VA-30kVA Input Voltage 1 Phase 2 Wire: 110V, 120V, 220V, 230V, 240V ± 10% (Option *) Input Frequency 50 Hz, 60 Hz± 5% 500VA Output Voltage&Current 120V Setting (Low grade): 0-150V, 4.2A; 240V Setting 0-300V (High grade): 0-300V, 2.1A 1kVA Output Voltage&Current 120V Setting (Low grade): 0-150V, 8.4A; 240V Setting 0-300V (High grade): 0-300V, 4.2A 2kVA Output Voltage&Current 110V Setting (Low grade): 0-150V, 16.8A; 220V Setting 0-300V (High grade): 0-300V, 8.4A 3kVA Output Voltage&Current 110V Setting (Low grade): 0-150V, 25A; 220V Setting 0-300V (High grade): 0-300V, 12.5A 5kVA Output Voltage&Current 110V Setting (Low grade): 0-150V, 41.6A; 220V Setting 0-300V (High grade): 0-300V, 20.8A 10kVA Output Voltage&Current 110V Set ting (Low grade): 0-150V, 83.2A; 220V Setting 0-300V (High grade): 0-300V, 41.6A 15kVA Output Voltage&Current 110V Setting (Low grade): 0-150V, 125A; 220V Setting 0-300V (High grade): 0-300V, 62.5A 20kVA Output Voltage&Current 110V Setting (Low grade): 0-150V, 166.4A; 220V Setting 0-300V (High grade): 0-300V, 83.2A 30kVA Output Voltage&Current 110V Setting (Low grade): 0-150V, 250A; 220V Setting 0-300V (High grade): 0-300V, 125A Output Frequency 50Hz, 60Hz Frequency Stability ≤±0.01% Harmonic Distortion Pure Sine Wave ≤2% Frequency meter 4 digit, digital frequency meter, resolution 0.1Hz/Step Voltmeter 4 digit, digital voltage meter, resolution 0.1V Ammeter 4 digit, digital ammeter, resolution 0.1A Watt meter 4 digit, digital Watt meter, resolution 0.1W Protection With overload, short circuit, over temperature; Instantaneous power failure protection and alarm device Working Temperature 0 - 40 deg.℃ Working Humidity 0 - 90% (Non condensation) 500VA Model HZ-60-500W 1kVA Converter Model HZ-60-1101 2kVA Converter Model HZ-50-1102 (Cabinet Type), HZ-60-1102 (Benchtop Type) 3kVA Converter Model HZ-50-1103 (Cabinet Type), HZ-60-1103 (Benchtop Type) 5kVA Converter Model HZ-50-1105 10kVA Converter Model HZ-50-1110 15kVA Converter Model HZ-50-1115 20kVA Converter Model HZ-50-1120 30kVA Converter Model HZ-50-1130 What does a single phase frequency converter do? Converts single-phase volt age and frequency for appliances and machines, providing stable pure sine wave output for international equipment and testing. What input and output voltages are supported? Supports 110V/120V/220V/230V/240V input. Output adjustable in two ranges: Low grade 0–150V, High grade 0–300V, suitable for step-up/step-down voltage conversion. Can it change frequency as well as voltage? Yes, it allows 50Hz & 60Hz conversion with adjustable voltage, making it suitable for global appliance use and R&D testing. Is it safe for sensitive devices? Provides pure sine wave output, voltage stability, and overload protection, ensuring safe operation for motors, pumps, electronics, and lab equipment. How to choose the right single phase converter? Match power rating, input voltage, and output needs. Professional technical guidance is available to ensure correct selection for your application. Important Hint: Regarding your application load type, in case of induction loads like motor-based and transformer, please mind the inrush current of the load/motor during starting up should be less than the converter's output rated current. Clarification: When the motor starts to spin up, it pulls high inrush current that may reach 6 times its rated value and lasts from few milliseconds to 1-3 seconds unless the motor was attached to starting controller like soft starter or VFD. Además, algunas otras cargas tienen alta corriente de irrupción como transformadores, amplificador electrónico (amplificador de tubo), una placa de circuito con varios condensadores y el condensador. Pautas de dimensionamiento del convertidor de frecuencia 1. Cargas del motor: 1). Arranque directo en línea (DOL): los motores consumen de 5 a 7veces la corriente nominal en el arranque. → Seleccione un convertidor con un tamaño de 5 a 8veces la potencia nominal del motor. 2). Uso de VFD o arrancador suave: la corriente de arranque se reduce a aproximadamente 1.5–2× corriente nominal La corriente de salida del → convertidor debe ser de al menos 1.5–2
Agregás al carrito
Sumás este y otros productos que querés traer.
Cotizás el envío
Calculamos flete aéreo y aranceles a Argentina.
Confirmás y pagás
Online con tarjeta, o por transferencia, con el total final a la vista.
Lo recibís en casa
Seguimiento en tiempo real. El despacho lo hacemos nosotros.
Los mejor puntuados del mismo tipo de producto