
Precio desde
$ 199.511
+ flete y aranceles — se calculan al cotizar
Opción 1
Compra protegida
Puerta a puerta
Aduana incluida
Product description IMPORTANT NOTE The vfd can only drive three-phase asynchronous motors and cannot be used as a power source.The VFD voltage output terminals (U,V,W) are for motor connection only. Do not connect any switches; otherwise short circuit.The fan will stop 1-2minute after the VFD stops running.If your motor is heavy load, pls choose a higher horsepower vfd than your motor'sThe VFD does not support brake resistor installation. If needed, contact the seller before purchase for customization. Technical Specification (for 220v motor) Applicable motor horse-power ≤ 4kw(5HP) Applicable motor rated current <25 amps Input valtage 220VAC(+/-5%) 1 or 3 phase(”R“,”T“ terminals for 1 phase,”R“,”S“.”T“ terminals for 3 phase) output valtage 3 phase 220v input Frequency 47-63Hz output frequency 0-400Hz, 0-50Hz/60Hz Circuit breaker suggestion 50A Wire specification suggestion 11 AWG Function introduction DC cooling fan DC cooling fan low noise, large air volume help vfd heat dissipation, improve product stability basic parameter for 400hz spindle For 400hz motor:Set pd005=400,pd004=400,pd003=400,pd072=400,pd144=3000,Then you can start driving the 400hz spindle. (Note:The VFD is already set to 400Hz by default when it is received) basic parameter for 3 phase 50/60Hz motor Drive 50/60hz motor:Set pd005=50/60,pd004=50/60,pd003=50/60,pd072=50/60 Diverse terminals, more functions for you to choose. Supports external switch start/stop (connect the "FOR" and "DCM" terminals,than set PD001=1)Supports mcah3 function and RS-485 communication (For more information, you can contact the seller, we will send you a video of the basic functions of VFD)Supports external potentiometer speed control Multi-function panel keyboard UP: Progressively increase data or function codes.DOWN: Progressively decrease data or function codes.SET: Enter menus step-by-step, save setting parameters.PRGM: Exit current(or present) state, switch among each states, mainly used to switch monitoring state, exit to previous menu.FWD/REV: 1, Press momentary button to start,release to stop; 2 Switch the rotation directionSHIFT: Switch monitoring parameters at monitoring state, at secondary menu, move data box to process editing position.Kindly Note: If you want to show RPM in the display,please press 'SHIFT' key Advanced motherboard features PID control; advanced calculus PID closed-loop arithmetic, quick responding speed and high suitabilityEasy PLC function can realize 16 legs of speed and inverter control functionRS485 communication port, adopting standard international MODBUS main circuit controlWith extremely strong anti-jamming capabilityLow output ratting torque0.5HZ-150%, low speed running abilityCarrier adjustable by 16KHZ, completely soundless working environmentBroad voltage working area, normal running in 304V-456VAuto voltage regulation (AVR) technique, for ensuring the inverter load capabilityWith perfect error protection and short circuit starting protection capability See More
Agregás al carrito
Sumás este y otros productos que querés traer.
Cotizás el envío
Calculamos flete aéreo y aranceles a Argentina.
Confirmás y pagás
Un asesor te contacta con el link de pago.
Lo recibís en casa
Tracking en tiempo real. Aduana incluida.