
Precio de origen
$ 317.462
+ flete y aranceles — se calculan al cotizar
Compra protegida
Puerta a puerta
Aduana incluida
Product description Overview ETCR2100A+ Clamp Earth Resistance Tester is our company's technology research and development team on technical quality of the pursuit of excellence, through continuous innovation to improve, upgrade with the old product. Its performance is mainly reflected in: Breakthrough in self-test the boot a long time to waiting, start immediately into the test.Breakthrough relay self-test mode, using the most advanced processing algorithms and digital integration technology.Breakthrough the old product too heavy issues, more in line with characteristics of hand-held devices.New design, panel operation with 6 buttons, better performance.Increase sound and light alarm function, with "beep-beep-beep” alarm sound.Increase the interference signal recognition indicator function, with "beep-beep-beep” indicator.Measurement range: 0.01Ω-200ΩStored data 99 Units. Lower power consumption, Maximum operating current less than 50mA. ETCR2100A+ Clamp Earth Resistance Tester is widely used in the grounding resistance measurement of the power, telecommunications, meteorology, oilfield, construction and the industrial and electrical equipment. In the measurement of a grounding system with loop, does not require breaking down the grounding down lead, and no need the auxiliary electrode. It is safe, fast and simple in use. The tester can measure ground faults which cannot be measured by traditional methods. It can be used in applications where traditional methods cannot be measured, because the ETCR series clamp grounding resistance meter measures the combined value of grounding body resistance and grounding lead resistance. Field Application The application of machine room earth resistance measurement The machine room of telecommunication system normally in the upper deck of the building. It is hard to use the meg-ohm meter to measure. However, ETCR Clamp meters are very convenient to test. The application of substation earth resistance measurement ETCR series clamp meter can use to test the situation of contact and connect of circuit. With the help of one test line, it can be used to test the connect situation of equipment in station and the grounding system. The application of building lightning protection grounding system measurement If the earth poles of the building are independent of each other, the earth resistance can be measured by clamp to testing any of the earth poles, and the earth resistance can also be measured by clamp the building roof lightning arrester.When the measured value is less than the allowable value, the earth electrode is qualified.If the measurement value of the clamp meter is larger than the allowable value, please use ingle earth point method to measurement. From the measuring principle, ETCR series Meter can only measure the loop resistance, the single-point grounding is not measured. However, users are able to use a testing line very near to the earth electrode of the grounding system to artificially create a loop for testing. For details, please read user manuals. ETCR2100A+ Ground Resistance Meter Technical Specifications Function Ground resistance test, Loop resistance test Resistance Range 0.010Ω-200Ω Resolution 0.001Ω Power Supply DC: 6V ( 4 PCS of LR6 Alkaline batteries) Clamp Size Φ32mm LCD Size 4 Digits LCD display, Screen : 47mm(L)×28.5mm(W) Accuracy ±1%rdg ± 0.01Ω Data Storage 99 sets Auto Power-Off Automatically power off after 5 minutes without any operate Power Consumption ≤50mA, Continuously working for 30 hours Working Environment -20℃~55℃ 20%rh~80%rh Store Environment -20℃~60℃; below 90%rh Alarm Threshold Setting Range Resistance: 1Ω~199Ω Audible and Visible Alarm "Beep-beep-beep” alarm sound, alarm symbol flashing, press AL key to turn on/off and setting Interference Signal Recognitio "Beep-beep-beep” indicator,NOISE symbol blinking Protection Level Double insulation Structural Feature Clamp CT Shift Automatic shift External Magnetic Field <40A/m External Electrical Field <1V/m Single Measurement Time 0.5 second Resistance Measure Frequency >1KHz Measured Current Frequency 50/60Hz Automatic Low Battery Voltage Indicator When the battery voltage is lower than 5.3V, the low battery voltage symbol is displayed Storage Full Indication Storage data full of 99 sets, flashed display "MEM" symbol Over Range Indication Exceed range indication “OLΩ”, “L0.01” or “OL A” Tester Weight 1030g (with batteries) Clamp Dimension 260mm×90mm×66mm Data Upload & Monitoring Software 1. Data Upload This listing of ETCR2100A+ ground resistance meter features USB interface. Users can upload data with such function.Boot up and enter test state, connect the computer with USB cable, and run the monitoring software. If the communication is normal, the computer can monitor the online resistance in real time.The monitoring software has functions such as online real-time monitoring, historical query, software alarm setting, historical data reading, and review, saving, and reporting.Histori
Agregás al carrito
Sumás este y otros productos que querés traer.
Cotizás el envío
Calculamos flete aéreo y aranceles a Argentina.
Confirmás y pagás
Un asesor te contacta con el link de pago.
Lo recibís en casa
Tracking en tiempo real. Aduana incluida.
De la misma marca, empezando por lo más reseñado
Los mejor puntuados del mismo tipo de producto
Mismo tipo de producto y precio parecido