
Precio de origen
$ 726.305
+ flete y aranceles — se calculan al cotizar
Compra protegida
Puerta a puerta
Aduana incluida
Product description Features 1.12.1 inch color LCD screen, full view display, high resolution 1024×768dpi; 2. Standard parameters: ECG, SpO2, NIBP, RESP, Temperature, Heart Rate; 3. No fan design, avoid hair debris involved in the equipment, no cross infection, to protect the health of animals and doctors; 4. The weak perfusion technique developed according to the characteristics of animal pulse in blood oxygen measurement has excellent anti-interference 5.NIBP uses pulse wave measurement technology to display the measurement process in real time, and has absolute judgment basis for the accuracy of the measurement results. 6.It has the function of intravenous assisted puncture and punctuality measurement 7. Frequency response 0.05-150Hz, heart rate measurement limit of 500 times/min; 8. Support ≥36 hours ECG waveform playback; 9. Simple and efficient interface display, standard interface, large font, respiratory oxygenation chart, trend coexistence, 7 leads ECG with the same screen; 10. The alarm tone and pulse rate tone are independent, the pulse rate tone continues to correspond when the alarm is muted, and the alarm tone can be activated normally when the pulse rate tone is muted. 15. Anti-defibrillation, electrotome, power grid, myoelectric interference; 11. Large capacity built-in lithium battery, continuous working time ≥240 minutes; 12. Large storage capacity: at least 800 hours of continuous monitoring of animals to meet the data storage requirements; 13. Optional built-in thermal matrix recorder, three trace waveform; 14. Very short boot time 6 seconds to enter the working state; 15. Reserve ETCO2 interface to support plug and play CO2 module; SPO2 Blood oxygen range: 0%-100% Resolution: 1% Accuracy: ±2% (not defined below 70%) Measuring range: 30 ~ 254bpmPulse accuracy: ±2bpm or ±5% Standard: animal use SPO2 probe Alarm value: upper and lower limits can be set, automatic memory RESP Measurement method:the thorax impedance method PR Measurement Range and Accuracy Measuring range: 0~ 150rpm. Measurement accuracy: 10~150 rpm the bigger one between ±2 rpm or ±2%; 0~9 rpm not define. whichever is larger; Suffocation alarm delay time Alarm limit can be set to: 2~150rpm ECG Lead selection: 3/5 lead standard; Up to 7 leads can be displayed on the same screen ECG value detection range: 20~500bpm. Gain selection: ×0.125, ×0.25, ×0.5, ×1, ×2, ×4, automatic. Ecg cable guide: 3/5 leads Standard configuration: 5 leads electrical cable, multifunctional ECG electrode clamp Alarm value: upper and lower limits can be set, automatic memory,have alarm review; NIBP Method: Oscillometric Measuring parameter: Systolic pressure, Diastolic pressure, Mean pressure Working mode: manual, automatic, continuous, whole point measurement Automatic measurement mode measurement interval: 1~480min multi-stage adjustable Standard configuration: disposable animal cuff (Range 4-8cm, Range 6-11cm, Range 7-13cm, Range 8-15cm) See More
Agregás al carrito
Sumás este y otros productos que querés traer.
Cotizás el envío
Calculamos flete aéreo y aranceles a Argentina.
Confirmás y pagás
Un asesor te contacta con el link de pago.
Lo recibís en casa
Tracking en tiempo real. Aduana incluida.
Lo que suele llevarse para tu pantalla · un solo envío para todo