
Precio desde
$ 691.701
+ flete y aranceles — se calculan al cotizar
Opción 1
Compra protegida
Puerta a puerta
Aduana incluida
The Generac HomeLink 50-amp manual transfer switch (model 9854) powers up to 10 hard-wired home circuits from any compatible portable generator during an outage — with a push-button rocker switch, no extension cords, and a clear upgrade path to fully automatic standby power. Do I need a 30-amp or 50-amp switch? If you plan to back up any 240V appliance — well pump, electric dryer, central air conditioner, or electric water heater — the 50-amp switch is the right choice. A 30-amp switch is limited to 7,200W and cannot support 240V double-pole circuits. The 50-amp HomeLink handles up to 12,000W at 120/240V single phase. How many circuits do I need? This switch comes pre-configured for 10 circuits and expands to 16 using interchangeable breakers — no rewiring required. Most households comfortably protect essential loads across 10 circuits: furnace, refrigerator, well pump, lighting, and two or three additional circuits. Will it work with my generator brand? Yes — the HomeLink is compatible with any portable generator that has a 50-amp CS6377 or compatible GFCI-protected outlet. It is multi-listed for Siemens, Eaton, and Square D GFCI and AFCI breakers. Is the enclosure rated for outdoor use? The transfer switch panel is NEMA 1 rated for indoor installation only — mount it beside your main breaker box. The power inlet box (included in kit 9855) is NEMA 3R rated for outdoor wall mounting. How does it prevent backfeed? A mechanical interlock ensures utility and generator power contacts cannot close at the same time, preventing backfeed into the utility grid per NEC Article 702. Is it manual or automatic? This is a manual switch — you push a button to transfer circuits during an outage. When you are ready to move to a standby generator, the HomeLink platform upgrades to automatic operation (up to 11 kW Generac) by replacing the controller only, without replacing the switch. Professional installation by a licensed electrician is recommended for all line-side connections and NEC code compliance. A 50A 2-pole breaker in the main load center is required and must be sourced by the installer.
Agregás al carrito
Sumás este y otros productos que querés traer.
Cotizás el envío
Calculamos flete aéreo y aranceles a Argentina.
Confirmás y pagás
Un asesor te contacta con el link de pago.
Lo recibís en casa
Tracking en tiempo real. Aduana incluida.
De la misma marca, empezando por lo más reseñado
Los mejor puntuados del mismo tipo de producto